BEREK, Frank Richard Nurak (2026) Sistem Pemantauan Kualitas Udara (Gas Amonia dan Karbon Dioksida) di Peternakan Ayam Berbasis IOT. Undergraduate thesis, Universitas Katolik Widya Mandira.
|
Text
ABSTRAK.pdf Download (638kB) |
|
|
Text
BAB I.pdf Download (169kB) |
|
|
Text
BAB II.pdf Restricted to Repository staff only Download (299kB) |
|
|
Text
BAB III.pdf Restricted to Repository staff only Download (342kB) |
|
|
Text
BAB IV.pdf Restricted to Repository staff only Download (228kB) |
|
|
Text
BAB V.pdf Restricted to Repository staff only Download (546kB) |
|
|
Text
BAB VI.pdf Download (123kB) |
|
|
Text
DAFTAR PUSTAKA.pdf Download (242kB) |
Abstract
Air quality in poultry houses often deteriorates due to the accumulation of ammonia (NH₃) and carbon dioxide (CO₂) gases, which can cause respiratory disorders, stress, decreased productivity, and even livestock mortality. Manual monitoring tends to be inaccurate and delayed; therefore, an automatic system capable of providing rapid air quality information is required. This study aims to design an Internet of Things (IoT)-based air quality monitoring system to detect NH₃ and CO₂ concentrations in real time and provide early warnings to farmers. The system utilizes MQ-137 and MQ135 sensors connected to an ESP32 microcontroller, equipped with an LCD display, a buzzer as a local alarm, and Telegram notifications. The test results show that the system can classify conditions into SAFE, WARNING, and DANGER levels. Under normal air conditions, CO₂ ranges from 900–940 ppm and NH₃ from 24–25 ppm (SAFE). Increasing CO₂ to approximately 1900 ppm results in a WARNING status. NH₃ testing produces 43 ppm (WARNING) and 84 ppm (DANGER), triggering alarms and notifications with a response time of 1–3 seconds. The initially high reading of the MQ-137 sensor in clean air can be resolved through potentiometer adjustment to stabilize the measurement. Overall, the system is feasible for poultry house air quality monitoring, provided proper sensor calibration is performed.
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | IoT, Air Quality,Ammonia (NH₃), Carbon Dioxide (CO₂), ESP3 |
| Subjects: | Q Science > QA Mathematics > QA75 Electronic computers. Computer science Q Science > QA Mathematics > QA76 Computer software |
| Divisions: | Fakultas Teknik > Program Studi Ilmu Komputer |
| Depositing User: | FRANK RICHARD NURAK BEREK |
| Date Deposited: | 13 Mar 2026 01:29 |
| Last Modified: | 13 Mar 2026 01:29 |